Asbestos - Laboratory Bridge Module

To purchase this option, go to your software then click on "Tool" / "Order products online" and select "Asbestos laboratory bridge"

I.   Access your account

To access your account, go to the customer management section and select the following option (If this menu is not available update your software (Tool / Update / Re-Download):

II.   Identify yourself or create your account

Note that you can contact your software publisher so that it is compatible with this platform.
We designed it so that all publishers (including our fellow real estate diagnostic software publishers) can use it and thus save time.

III.   Add the laboratories (check availability by calling your laboratory)

In order to add a laboratory, we advise you to contact it to obtain the identifiers of your account. Select the laboratory from the list, then complete the required fields.

 

IV.   Carry out your asbestos diagnosis

Create materials, ACBM and their associated samples as usual or by following the WikiLiciel Asbestos Module.

 

V.   Send the samples / samples to the laboratory

Please go to the " Samples / Analysis " tab " Samples " sub-tab of the Asbestos module.

  • step 1: select the samples you want to send to the laboratory


You can use the buttons from the top left, or the Ctrl / Shift key on your keyboard to make multiple selections.

  • step 2: click on the " Send " arrow and select your pre-registered laboratory

In the "Selected Laboratory" drop-down menu, you will find the list of laboratories previously configured on your LICIELAmiante interface.

You can communicate additional information to the laboratory chosen from the drop-down menu in the “ Order comments ” section.
Fill in the data of the " Contact to be mentioned on the report ". These data will be saved for future files.
By clicking on the " Send to laboratory " button , the laboratory will be informed of the sending of samples.

 

VI.   Printing labels and order form

The "LABORATORY BRIDGE" order form is automatically generated and displayed on the screen.
You can reprint it by clicking on the button below:

Only this document must be sent to the laboratory, it contains the API reference that the laboratory will use to send you the results in a dematerialized manner.
If you do not use this BDC, the lab will run the risk of processing your order manually and only returning the scan PDFs to you without using the lab bridge.

VII.   Reception of analyzes via the laboratory bridge

The laboratory is now the owner of your physical samples and your digital samples.
Once the analysis has been carried out, the laboratory will send you the analysis PDFs by email (this is always the case).
Spend a time that can go from 1 hour to 5 hours (depending on the laboratory) all the results will be recoverable on your software according to two methods:

Manual method

In the field part of your file, click on the following button to receive the available results.

Automatic method

You must set up the direct debit synchronization software.
In the "LICIEL V4 - File management" section, open the synchronization software by going to Field Section / LICIEL Asbestos / Retrieve Asbestos Lab Results.

The software "LICIEL ASBESTOS" will open to run in the background in order to watch for the availability of results and to warn you.

Every 300 seconds this one analyzes the results returned by your laboratories and a tooltip will notify you of the availability of a result that you can download automatically.

A right click on the selected file will allow you to automate the opening of this file and the downloading of the results and PDFs of the laboratory.
You just have to print the final report.

 

VIII.   Additional Options

  • Cancel an order

A right click on the "send" button cancels an order on the LICIEL side.
Remember to notify the laboratory that you have made this cancellation, for its part it has already received the order and will respond to it without any action on your part.

  • Force retrieval of results


A right click on the "receive" button allows to force the recovery of the results with or without reinitialization of the results of the server.
Case 1 makes it possible to search for the results retrieved on the LICIEL servers already retrieved from the laboratory server.
Case 2 deletes the results retrieved from the LICIEL servers and will search on the laboratory servers.

  • 1 R / Sample


If your laboratory allows it, by checking this box, you will recover 1 PDF per sample.
Otherwise, only 1 PDF (cumulative of all results) will be assigned to the samples

  • Keep layers


You send 6 samples to the laboratory.
2 of these 6 samples will be analyzed separately by the laboratory.

By checking this option, you will receive 6 results for your 6 samples.
The 2 samples analyzed in several layers will have the listing of the layers in the laboratory commentary.
The software will respond to both of your samples taking the "worst" result from each layer.

Both layers are negative:

One of the 3 layers is positive:

If this option is unchecked, you will receive the 4 samples nominally, and for the 2 multi-layer samples, you will receive one result per layer.
LICIEL will therefore proceed to the "split" of the lines which will multiply the samples and the materials to properly separate the layers.

Before sending:

After reception:

Detail of the 2 layers:
 
This makes it possible to separate the lines well but makes reading the file more explicit but therefore a little more complex.